Aircool India
Andheri East, Mumbai, Maharashtra
SEND SMS
SEND EMAIL

Castle Cold Room Accessories

Leading Authorized Wholesale Dealer of sulfur hexafluoride, cold room electrical panel, cold room panels cold room panels and cold room control panel from Mumbai.

Sulfur Hexafluoride

Sulfur Hexafluoride
  • Sulfur Hexafluoride
Ask For Price
Product Price :Get Latest Price

Product Details:

Packaging Size10-61 kilogram
BrandAircool India
Packaging TypeCylinder
TypeChemical gas
FormGas

Owing to our expertise in this field, our firm is engaged in supplying an extensive array of Sulfur Hexafluoride
Request
Callback
Yes! I am Interested

Cold Room Electrical Panel

Cold Room Electrical Panel
  • Cold Room Electrical Panel
Ask For Price
Product Price :Get Latest Price

Product Details:

ApplicationCool Room
Working Voltage220VAC +- 10%,50/60Hz
Temperature Resolution0.1deg C
Power ConsumptionLess than 5w

Manufacturer & Supplier of CR-2020 Cold Room Control Panel. We even provide coustomize panels for Cold rooms if incase requir by any specific logic & design.
Request
Callback
Yes! I am Interested

Cold Room Panels Cold Room Panels

Cold Room Panels Cold Room Panels
  • Cold Room Panels Cold Room Panels
Ask For Price
Product Price :Get Latest Price

Product Details:

Voltage230 V
Cooling Capability7.02 kW
Dimension575 x 36 x 397 mm

Manufacturer & Supplier of CR-2020 Cold Room Control Panel. We even provide customize panels for Cold rooms if in case require by any specific logic & design.
Request
Callback
Yes! I am Interested

Cold Room Control Panel

Cold Room Control Panel
  • Cold Room Control Panel
Ask For Price
Product Price :Get Latest Price

Product Details:

External Size261 x 167.5 x 70mm
Refrigeration Output50A / 240VAC
TypeControl Box

The controller controls the defrost in the system based on either an electrical heater where the compressor is stopped, or at cycle inversion using warm gas where the compressor keeps on working. There are safety features which include shutting down the system incase of a fault from a pressure control or similar device. A series of “safety controls” (delay at start-up, minimum disable time, minimum time between activation) protects the compressors from close starts. In case of probe error or temperature alarm, the instrument signals the event through acoustic signal and by closing the relay contact. By pressing the mute key, the buzzer is silenced. A number of parameters are displayed alphanumerically to set up the instrument for each specific function. Computer Connectivity over RS485 and Remote monitoring(Optional). Single Operation Quick Freeze Mode(Press QF Key for 2 sec), set system in quick freeze mode which is time based for that period new set point will be lower than running set point and system will try to achieve that set point, after time period over set point will be normal set point
Request
Callback
Yes! I am Interested
X

Explore more products

Harris Brazing Flux
Harris Brazing Flux
Get Best Quote
410 Refrigerant Gas
410 Refrigerant Gas
Get Best Quote
r32 GAS
r32 GAS
Get Best Quote
r123
r123
Get Best Quote


Reach Us
Vikas Linga (Partner)
1/58-59, Andheri Kurla Road, J. B. Nagar
Andheri East, Mumbai- 400059, Maharashtra, India



Call Us

Share Us

F GT L


Send E-mailSend SMS